Figure 42 - Set Mail Interval Email Sample
Figure 43 - Emap Edit Alarm Conguration
30 | SecurityMan
this time will be accumulates and all the pictures will be
sent when the time interval expired. For example; if the
Set Mail Interval is set to 300 seconds (5 minutes) and an
event occurred and emailed out at 7:07:07am, any other
event(s) that occurred after this rst occurrence will ac-
cumulates in pictures and events and will be sent out 5
minutes later as illustrated below:
NOTICE
Only one picture will be sent per every alarm event. If Set
Mail Interval is in use, an accumulated pictures and events list
will be sent out in a single email with multiple events list and
multiple pictures.
Emap Function Conguration
E-map is use to show geographic area of homes, buildings,
region and etc. which includes locations of cameras layout
in the geographic region. E-map essentially provides geo-
graphic area with camera layouts monitored by SuperDVR
system in a form of a map. This feature is simple to use
and operates with direct status display and it is generally
graded or tiered in the form of a tree diagram.
To setup Emap select “Emap” tab from the Alarm Con-
guration panel to enter E-map. Select the “Auto-hide”
to enable E-map and congure the Holding time which
ranges from 5, 10, 15, 20, and 30 seconds. Holding time is
the time that E-map will display (pop-up) when an event
occurs until the event expired. To edit E-map simply click
on the “Emap Edit” button as illustrated below in gure
43.